;------------------------------------------------------------------------------ ; This GSD (General Station Description) is provided by PI C3PG7 "PA Profile". ; This GSD is available for download at PI web server. ; The Profile GSDs cover the common subset of functions of devices of ; a specific PA device type providing interchangeability. ; ; This file describes the device type: ; Liquid analyzer for oxygen concentration measurement ; with 2 Analog Inputs ; Physical layer MBP. ; This file becomes valid with the PA profile version 4.0. ; ; Last modification: 2017-10-20 ;------------------------------------------------------------------------------ #Profibus_DP ;Standard definitions, valid for all device types with MBP GSD_Revision = 5 Vendor_Name = "Profile Process Control Devices" Revision = "PA 4.x" Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "-" Software_Release = "-" 31.25_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 ;needed to support spec. network devices 500_supp = 1 ;needed to support spec. network devices 1.5M_supp = 1 ;needed to support spec. network devices 3M_supp = 1 ;needed to support spec. network devices 6M_supp = 1 ;needed to support spec. network devices 12M_supp = 1 ;needed to support spec. network devices MaxTsdr_31.25 = 100 MaxTsdr_45.45 = 250 ;exception for spec. network devices MaxTsdr_93.75 = 1000 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 250 Modular_Station = 1 Slave_Family = 12@Profile4 ;end of standard definitions ;Device type specific definitions Model_Name = "Liquid analyzer oxygen (PhyL 1)" Ident_Number = 0xB372 Bitmap_Device = "PA_B372n" Max_Module = 2 Max_Input_Len = 10 ;2*AI(2*5) Max_Output_Len = 0 Max_Data_Len = 10 Max_Diag_Data_Len = 28 Modul_Offset = 1 Max_User_Prm_Data_Len = 24 Ext_User_Prm_Data_Const(0) = 0x80 ;DPV1 Status 1 Ext_User_Prm_Data_Const(1) = 0x00 ;DPV1 Status 2 Ext_User_Prm_Data_Const(2) = 0x08 ;DPV1 Status 3 ;--- Startup parameter of the Physical Block (Slot 0) PrmText = 1 ;STARTUP_PARAM_VALIDITY Text(0) = "Ignored" Text(1) = "Applied" EndPrmText ExtUserPrmData = 1 "Startup parameters" Unsigned8 0 0-1 Prm_Text_Ref = 1 EndExtUserPrmData Ext_User_Prm_Data_Const(3) = 5,66,0,0,0x00 Ext_User_Prm_Data_Ref(7) = 1 ;STARTUP_PARAM_VALIDITY (Unsigned8) ;--- Startup parameter of the liquid analyzer transducer block - (Slot 1) PrmText = 2 ;Analysis value units Text(1342) = "%" Text(1558) = "mg/l" Text(1559) = "ug/l)" Text(1423) = "ppm" Text(1424) = "ppb" EndPrmText ExtUserPrmData = 2 "Unit (conductivity)" Unsigned16 1342 0-65535 Prm_Text_Ref = 2 EndExtUserPrmData PrmText = 3 ;Temperature units Text(1000) = "kelvin" Text(1001) = "degree Celsius" Text(1002) = "degree Fahrenheit" Text(1003) = "degree Rankine" EndPrmText ExtUserPrmData = 3 "Unit (temperature)" Unsigned16 1001 0-65535 Prm_Text_Ref = 3 EndExtUserPrmData Ext_User_Prm_Data_Const(8) = 8,68,1,0,0x05,0x3e,0x03,0xe9 Ext_User_Prm_Data_Ref(12) = 2 ;analysis value unit (Unsigned16) Ext_User_Prm_Data_Ref(14) = 3 ;temperature unit (Unsigned16) Prm_Block_Structure_supp = 1 PrmCmd_supp = 1 ;slave supports PrmCmd Slave_Max_Switch_Over_Time = 20 ;=200 ms Slave_Redundancy_supp = 1 ;slave is not redundant but can be connected to a flying master Info_Text = "Liquid analyzer for oxygen concentration measurement with \ PROFIBUS PA (MBP) communication interface." Ident_Maintenance_supp = 1 ;----------- Description of extended DP features: --------------------- ; DPV1_Slave = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 128 C1_Response_Timeout = 1000 C2_Read_Write_supp = 1 C2_Max_Data_Len = 128 C2_Max_Count_Channels = 1 Max_Initiate_PDU_Length = 52 C2_Response_Timeout = 1000 DPV1_Data_Types = 0 WD_Base_1ms_supp = 0 Check_Cfg_Mode = 0 ;----------- Description of device related diagnosis: --------------------- ; Unit_Diag_Bit(16) = "Status appears" Unit_Diag_Bit(17) = "Status disappears" Unit_Diag_Bit(35) = "Restart" ;DIA_WARMSTART Unit_Diag_Bit(36) = "Application reset" ;DIA_COLDSTART Unit_Diag_Bit(37) = "Maintenance required" ;DIA_MAINTENANCE Unit_Diag_Bit(40) = "Maintenance alarm" ;DIA_MAINTENANCE_ALARM Unit_Diag_Bit(41) = "Maintenance demanded" ;DIA_MAINTENANCE_DEMANDED Unit_Diag_Bit(42) = "Function check" ;DIA_FUNCTION_CHECK Unit_Diag_Bit(43) = "Out of specification" ;DIA_OUT_OF_SPEC Unit_Diag_Bit(44) = "Parameter update" ;DIA_UPDATE_EVENT Unit_Diag_Bit(55) = "Extension available" ;NE107_COMMON Unit_Diag_Bit(56) = "Sensor element exciter faulty" Unit_Diag_Bit_Help(56) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(57) = "Error in evaluation electronics" Unit_Diag_Bit_Help(57) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(58) = "Error in internal energy supply" Unit_Diag_Bit_Help(58) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(59) = "Error in sensor element" Unit_Diag_Bit_Help(59) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(60) = "Error in actuator element" Unit_Diag_Bit_Help(60) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(61) = "Faulty installat e.g. dead space" Unit_Diag_Bit_Help(61) = "Check installation." Unit_Diag_Bit(62) = "Parameter setting error" Unit_Diag_Bit_Help(62) = "Check parameter settings for consistency." Unit_Diag_Bit(63) = "Signal path broken or short cut" Unit_Diag_Bit_Help(63) = "Check signal path." Unit_Diag_Bit(64) = "Overloading" Unit_Diag_Bit_Help(64) = "Check load." Unit_Diag_Bit(65) = "Wrong polarity of aux power" Unit_Diag_Bit_Help(65) = "Check polarity." Unit_Diag_Bit(66) = "Maximum line length exceeded" Unit_Diag_Bit_Help(66) = "Check line length." Unit_Diag_Bit(67) = "Corrosion/abrasion by medium" Unit_Diag_Bit_Help(67) = "Replacement is recommended." Unit_Diag_Bit(68) = "Fouling on sensor element" Unit_Diag_Bit_Help(68) = "Cleaning is recommended." Unit_Diag_Bit(69) = "Auxil medium missing or insuffic" Unit_Diag_Bit_Help(69) = "Check auxiliary medium." Unit_Diag_Bit(70) = "Wear reserve used up (operation)" Unit_Diag_Bit_Help(70) = "Plan maintenance." Unit_Diag_Bit(71) = "Wear reserve used up (wear)" Unit_Diag_Bit_Help(71) = "Plan maintenance." Unit_Diag_Bit(72) = "Error in peripherals" Unit_Diag_Bit_Help(72) = "Check peripherals." Unit_Diag_Bit(73) = "Electromag interference too high" Unit_Diag_Bit_Help(73) = "Lower external electromagnetic interference." Unit_Diag_Bit(74) = "Temperature of medium too high" Unit_Diag_Bit_Help(74) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(75) = "Ambient temperature too high" Unit_Diag_Bit_Help(75) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(76) = "Vibration/Impact load too high" Unit_Diag_Bit_Help(76) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(77) = "Auxiliary power range off-spec" Unit_Diag_Bit_Help(77) = "Check power supply" Unit_Diag_Bit(78) = "Auxiliary medium missing" Unit_Diag_Bit_Help(78) = "Check auxiliary medium." Unit_Diag_Bit(79) = "Excessive temperature shock" Unit_Diag_Bit_Help(79) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(80) = "Deviation from measurement" Unit_Diag_Bit_Help(80) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(81) = "Humidity in electronics area" Unit_Diag_Bit_Help(81) = "Replacement is recommended." Unit_Diag_Bit(82) = "Medium in electronics area" Unit_Diag_Bit_Help(82) = "Replacement is recommended." Unit_Diag_Bit(83) = "Mechanical damage" Unit_Diag_Bit_Help(83) = "Replacement is recommended." Unit_Diag_Bit(84) = "Communication error" Unit_Diag_Bit_Help(84) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(85) = "Foreign material in electro area" Unit_Diag_Bit_Help(85) = "Replacement is recommended." ;NE107_CONTACT_THERMOMETER (device specific) Unit_Diag_Bit(104) = "Immersion depth too limited" Unit_Diag_Bit(105) = "Unequate medium around sensor" Unit_Diag_Bit(106) = "Temp disturb not representative" Unit_Diag_Bit(107) = "Inadequate thermal contact" Unit_Diag_Bit(108) = "Sensor close to heat source/sink" Unit_Diag_Bit(109) = "External temperature influence" Unit_Diag_Bit(110) = "Unsufficient thermocupling" Unit_Diag_Bit(111) = "Thermocoupling too high" Unit_Diag_Bit(112) = "Friction heat by flowing gases" Unit_Diag_Bit(113) = "Thermalcapac of sensor too high" Unit_Diag_Bit(114) = "Deposits" Unit_Diag_Bit(115) = "Systemrelated resonant vibration" Unit_Diag_Bit(116) = "Resonantvibrat excited by flow" Unit_Diag_Bit(117) = "Leakage" Unit_Diag_Bit(118) = "Abrasion" Unit_Diag_Bit(119) = "Corrosion" Unit_Diag_Bit(120) = "Flow approach speed too high" Unit_Diag_Bit(121) = "Insulation resistant too low" Unit_Diag_Bit(122) = "Insulation resistant too low" Unit_Diag_Bit(123) = "Parasitic thermal elements" Unit_Diag_Bit(124) = "Parasitic galvanic elements" Unit_Diag_Bit(125) = "Short circuit" Unit_Diag_Bit(126) = "Shorted coil and break" Unit_Diag_Bit(127) = "Line/contact resistant too high" Unit_Diag_Bit(128) = "Compression spring failure" Unit_Diag_Bit(129) = "Drift of sensor charact curve" Unit_Diag_Bit(130) = "Insuff contact of meas insert" Unit_Diag_Bit(131) = "Meas insert mechanical seized" Unit_Diag_Bit(132) = "Measuring insert in thermowell" Unit_Diag_Bit(133) = "Measuring insert too short" Unit_Diag_Bit(134) = "Resistance wire abrasion" Unit_Diag_Bit(135) = "Mechanic stress character curve" Unit_Diag_Bit(136) = "Thermal stress character curve" Unit_Diag_Bit(137) = "Intrinsic heating too severe" Unit_Diag_Bit(138) = "EMI on measuring circuit" Unit_Diag_Bit(139) = "Faulty linearisation" Unit_Diag_Bit(140) = "Incorrect sensor position" Unit_Diag_Bit(141) = "Faulty comparative point temp" Unit_Diag_Bit(142) = "Faulty compar of line resistance" Unit_Diag_Bit(143) = "Unsymmet supply line resistance" Unit_Diag_Bit(144) = "Wrong material of compens line" Unit_Diag_Bit(145) = "Damage to supply lines" Unit_Diag_Bit(146) = "Capacitive feedback" Unit_Diag_Bit(147) = "Potential transfer" Unit_Diag_Bit(148) = "Potential differences exceeded" Unit_Diag_Bit(149) = "Impermiss mix of wire systems" Unit_Diag_Bit(150) = "Reserve polarity of lines" Unit_Diag_Bit(151) = "Reserve polarity of RTD lines" ;--------------- UnitDiagType=254 X_Unit_Diag_Bit(35) = "Restart" ;DIA_WARMSTART X_Unit_Diag_Bit(36) = "Application reset" ;DIA_COLDSTART X_Unit_Diag_Bit(37) = "Maintenance required" ;DIA_MAINTENANCE X_Unit_Diag_Bit(40) = "Maintenance alarm" ;DIA_MAINTENANCE_ALARM X_Unit_Diag_Bit(41) = "Maintenance demanded" ;DIA_MAINTENANCE_DEMANDED X_Unit_Diag_Bit(42) = "Function check" ;DIA_FUNCTION_CHECK X_Unit_Diag_Bit(43) = "Out of specification" ;DIA_OUT_OF_SPEC X_Unit_Diag_Bit(44) = "Parameter update" ;DIA_UPDATE_EVENT X_Unit_Diag_Bit(55) = "Extension available" ;--- NE107_COMMON X_Unit_Diag_Bit(56) = "Sensor element exciter faulty" X_Unit_Diag_Bit_Help(56) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(57) = "Error in evaluation electronics" X_Unit_Diag_Bit_Help(57) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(58) = "Error in internal energy supply" X_Unit_Diag_Bit_Help(58) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(59) = "Error in sensor element" X_Unit_Diag_Bit_Help(59) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(60) = "Error in actuator element" X_Unit_Diag_Bit_Help(60) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(61) = "Faulty installat e.g. dead space" X_Unit_Diag_Bit_Help(61) = "Check installation." X_Unit_Diag_Bit(62) = "Parameter setting error" X_Unit_Diag_Bit_Help(62) = "Check parameter settings for consistency." X_Unit_Diag_Bit(63) = "Signal path broken or short cut" X_Unit_Diag_Bit_Help(63) = "Check signal path." X_Unit_Diag_Bit(64) = "Overloading" X_Unit_Diag_Bit_Help(64) = "Check load." X_Unit_Diag_Bit(65) = "Wrong polarity of aux power" X_Unit_Diag_Bit_Help(65) = "Check polarity." X_Unit_Diag_Bit(66) = "Maximum line length exceeded" X_Unit_Diag_Bit_Help(66) = "Check line length." X_Unit_Diag_Bit(67) = "Corrosion/abrasion by medium" X_Unit_Diag_Bit_Help(67) = "Replacement is recommended." X_Unit_Diag_Bit(68) = "Fouling on sensor element" X_Unit_Diag_Bit_Help(68) = "Cleaning is recommended." X_Unit_Diag_Bit(69) = "Auxil medium missing or insuffic" X_Unit_Diag_Bit_Help(69) = "Check auxiliary medium." X_Unit_Diag_Bit(70) = "Wear reserve used up (operation)" X_Unit_Diag_Bit_Help(70) = "Plan maintenance." X_Unit_Diag_Bit(71) = "Wear reserve used up (wear)" X_Unit_Diag_Bit_Help(71) = "Plan maintenance." X_Unit_Diag_Bit(72) = "Error in peripherals" X_Unit_Diag_Bit_Help(72) = "Check peripherals." X_Unit_Diag_Bit(73) = "Electromag interference too high" X_Unit_Diag_Bit_Help(73) = "Lower external electromagnetic interference." X_Unit_Diag_Bit(74) = "Temperature of medium too high" X_Unit_Diag_Bit_Help(74) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(75) = "Ambient temperature too high" X_Unit_Diag_Bit_Help(75) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(76) = "Vibration/Impact load too high" X_Unit_Diag_Bit_Help(76) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(77) = "Auxiliary power range off-spec" X_Unit_Diag_Bit_Help(77) = "Check power supply" X_Unit_Diag_Bit(78) = "Auxiliary medium missing" X_Unit_Diag_Bit_Help(78) = "Check auxiliary medium." X_Unit_Diag_Bit(79) = "Excessive temperature shock" X_Unit_Diag_Bit_Help(79) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(80) = "Deviation from measurement" X_Unit_Diag_Bit_Help(80) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(81) = "Humidity in electronics area" X_Unit_Diag_Bit_Help(81) = "Replacement is recommended." X_Unit_Diag_Bit(82) = "Medium in electronics area" X_Unit_Diag_Bit_Help(82) = "Replacement is recommended." X_Unit_Diag_Bit(83) = "Mechanical damage" X_Unit_Diag_Bit_Help(83) = "Replacement is recommended." X_Unit_Diag_Bit(84) = "Communication error" X_Unit_Diag_Bit_Help(84) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(85) = "Foreign material in electro area" X_Unit_Diag_Bit_Help(85) = "Replacement is recommended." ;NE107_CONTACT_THERMOMETER (device specific) X_Unit_Diag_Bit(104) = "Immersion depth too limited" X_Unit_Diag_Bit(105) = "Unequate medium around sensor" X_Unit_Diag_Bit(106) = "Temp disturb not representative" X_Unit_Diag_Bit(107) = "Inadequate thermal contact" X_Unit_Diag_Bit(108) = "Sensor close to heat source/sink" X_Unit_Diag_Bit(109) = "External temperature influence" X_Unit_Diag_Bit(110) = "Unsufficient thermocupling" X_Unit_Diag_Bit(111) = "Thermocoupling too high" X_Unit_Diag_Bit(112) = "Friction heat by flowing gases" X_Unit_Diag_Bit(113) = "Thermalcapac of sensor too high" X_Unit_Diag_Bit(114) = "Deposits" X_Unit_Diag_Bit(115) = "Systemrelated resonant vibration" X_Unit_Diag_Bit(116) = "Resonantvibrat excited by flow" X_Unit_Diag_Bit(117) = "Leakage" X_Unit_Diag_Bit(118) = "Abrasion" X_Unit_Diag_Bit(119) = "Corrosion" X_Unit_Diag_Bit(120) = "Flow approach speed too high" X_Unit_Diag_Bit(121) = "Insulation resisant too low" X_Unit_Diag_Bit(122) = "Insulation resisant too low" X_Unit_Diag_Bit(123) = "Parasitic thermal elements" X_Unit_Diag_Bit(124) = "Parasitic galvanic elements" X_Unit_Diag_Bit(125) = "Short circuit" X_Unit_Diag_Bit(126) = "Shorted coil and break" X_Unit_Diag_Bit(127) = "Line/contact resistant too high" X_Unit_Diag_Bit(128) = "Compression spring failure" X_Unit_Diag_Bit(129) = "Drift of sensor charact curve" X_Unit_Diag_Bit(130) = "Insuff contact of meas insert" X_Unit_Diag_Bit(131) = "Meas insert mechanical seized" X_Unit_Diag_Bit(132) = "Measuring insert in thermowell" X_Unit_Diag_Bit(133) = "Measuring insert too short" X_Unit_Diag_Bit(134) = "Resistance wire abrasion" X_Unit_Diag_Bit(135) = "Mechanic stress character curve" X_Unit_Diag_Bit(136) = "Thermal stress character curve" X_Unit_Diag_Bit(137) = "Intrinsic heating too severe" X_Unit_Diag_Bit(138) = "EMI on measuring circuit" X_Unit_Diag_Bit(139) = "Faulty linearisation" X_Unit_Diag_Bit(140) = "Incorrect sensor position" X_Unit_Diag_Bit(141) = "Faulty comparative point temp" X_Unit_Diag_Bit(142) = "Faulty compar of line resistance" X_Unit_Diag_Bit(143) = "Unsymmet supply line resistance" X_Unit_Diag_Bit(144) = "Wrong material of compens line" X_Unit_Diag_Bit(145) = "Damage to supply lines" X_Unit_Diag_Bit(146) = "Capacitive feedback" X_Unit_Diag_Bit(147) = "Potential transfer" X_Unit_Diag_Bit(148) = "Potential differences exceeded" X_Unit_Diag_Bit(149) = "Impermiss mix of wire systems" X_Unit_Diag_Bit(150) = "Reserve polarity of lines" X_Unit_Diag_Bit(151) = "Reserve polarity of RTD lines" EndUnitDiagType ;------------------------------------------------------------------------- ; ;max module text length-----------------" Module="Not in cyclic data transfer " 0x00 ;Empty module 0 Info_Text="No cyclic data selected for this slot. Function disabled" EndModule Module="Oxygen concentration" 0x42,0x84,0x08,0x05 1 EndModule Module="Temperature" 0x42,0x84,0x08,0x05 2 EndModule ;----------- Description of the module assignment: --------------------- ; SlotDefinition Slot(1) = "" 1 1 Slot(2) = "" 2 0,2 EndSlotDefinition