;------------------------------------------------------------------------------ ; This GSD (General Station Description) is provided by PI C3PG7 "PA Profile". ; This GSD is available for download at PI web server. ; The Profile GSDs cover the common subset of functions of devices of ; a specific PA device type providing interchangeability. ; ; This file describes the device type: ; Buoyancy level transmitter ; with 1 Analog Input ; Physical layer RS-485. ; This file becomes valid with the PA profile version 4.0. ; ; Last modification: 2017-10-20 ;------------------------------------------------------------------------------ #Profibus_DP ;Standard definitions, valid for all device types with RS-485 GSD_Revision = 5 Vendor_Name = "Profile Process Control Devices" Revision = "PA 4.x" Protocol_Ident = 0 Station_Type = 0 FMS_supp = 0 Hardware_Release = "-" Software_Release = "-" 9.6_supp = 1 19.2_supp = 1 45.45_supp = 1 93.75_supp = 1 187.5_supp = 1 ;needed to support spec. network devices 500_supp = 1 ;needed to support spec. network devices 1.5M_supp = 1 ;needed to support spec. network devices 3M_supp = 1 ;needed to support spec. network devices 6M_supp = 1 ;needed to support spec. network devices 12M_supp = 1 ;needed to support spec. network devices MaxTsdr_9.6 = 60 MaxTsdr_19.2 = 60 MaxTsdr_45.45 = 250 ;exception for spec. network devices MaxTsdr_93.75 = 60 MaxTsdr_187.5 = 60 MaxTsdr_500 = 100 MaxTsdr_1.5M = 150 MaxTsdr_3M = 250 MaxTsdr_6M = 450 MaxTsdr_12M = 800 Redundancy = 0 Repeater_Ctrl_Sig = 0 24V_Pins = 0 Freeze_Mode_supp = 0 Sync_Mode_supp = 0 Auto_Baud_supp = 1 Set_Slave_Add_supp = 1 Min_Slave_Intervall = 6 Modular_Station = 1 Slave_Family = 12@Profile4 ;end of standard definitions ;Device type specific definitions Model_Name = "Buoyancy level (PhyL 0)" Ident_Number = 0xB324 Bitmap_Device = "PA_B324n" Max_Module = 1 Max_Input_Len = 5 ;1*AI(1*5) Max_Output_Len = 0 Max_Data_Len = 5 Max_Diag_Data_Len = 31 Modul_Offset = 1 Max_User_Prm_Data_Len = 22 Ext_User_Prm_Data_Const(0) = 0x80 ;DPV1 Status 1 Ext_User_Prm_Data_Const(1) = 0x00 ;DPV1 Status 2 Ext_User_Prm_Data_Const(2) = 0x08 ;DPV1 Status 3 ;--- Startup parameter of the Physical Block (Slot 0) PrmText = 1 ;STARTUP_PARAM_VALIDITY Text(0) = "Ignored" Text(1) = "Applied" EndPrmText ExtUserPrmData = 1 "Startup parameters" Unsigned8 0 0-1 Prm_Text_Ref = 1 EndExtUserPrmData Ext_User_Prm_Data_Const(3) = 5,66,0,0,0x00 Ext_User_Prm_Data_Ref(7) = 1 ;STARTUP_PARAM_VALIDITY (Unsigned8) ;--- Startup parameter of the transducer block - Buoyancy level (Slot 1) PrmText = 2 ;Level units Text(1010) = "m" Text(1018) = "ft" EndPrmText ExtUserPrmData = 2 "Unit (Level)" Unsigned16 1010 0-65535 Prm_Text_Ref = 2 EndExtUserPrmData Ext_User_Prm_Data_Const(8) = 6,68,1,0,0x03,0xf2 Ext_User_Prm_Data_Ref(12) = 2 ;level unit (Unsigned16) Prm_Block_Structure_supp = 1 PrmCmd_supp = 1 ;slave supports PrmCmd Slave_Max_Switch_Over_Time = 20 ;=200 ms Slave_Redundancy_supp = 1 ;slave is not redundant but can be connected to a flying master Info_Text = "Buoyancy level transmitter with PROFIBUS DP \ communication interface." Ident_Maintenance_supp=1 ;----------- Description of extended DP features: --------------------- ; DPV1_Slave = 1 C1_Read_Write_supp = 1 C1_Max_Data_Len = 128 C1_Response_Timeout = 1000 C2_Read_Write_supp = 1 C2_Max_Data_Len = 128 C2_Max_Count_Channels = 1 Max_Initiate_PDU_Length = 52 C2_Response_Timeout = 1000 DPV1_Data_Types = 0 WD_Base_1ms_supp = 0 Check_Cfg_Mode = 0 ;----------- Description of device related diagnosis: --------------------- ; Unit_Diag_Bit(16) = "Status appears" Unit_Diag_Bit(17) = "Status disappears" Unit_Diag_Bit(35) = "Restart" ;DIA_WARMSTART Unit_Diag_Bit(36) = "Application reset" ;DIA_COLDSTART Unit_Diag_Bit(37) = "Maintenance required" ;DIA_MAINTENANCE Unit_Diag_Bit(40) = "Maintenance alarm" ;DIA_MAINTENANCE_ALARM Unit_Diag_Bit(41) = "Maintenance demanded" ;DIA_MAINTENANCE_DEMANDED Unit_Diag_Bit(42) = "Function check" ;DIA_FUNCTION_CHECK Unit_Diag_Bit(43) = "Out of specification" ;DIA_OUT_OF_SPEC Unit_Diag_Bit(44) = "Parameter update" ;DIA_UPDATE_EVENT Unit_Diag_Bit(55) = "Extension available" ;NE107_COMMON Unit_Diag_Bit(56) = "Sensor element exciter faulty" Unit_Diag_Bit_Help(56) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(57) = "Error in evaluation electronics" Unit_Diag_Bit_Help(57) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(58) = "Error in internal energy supply" Unit_Diag_Bit_Help(58) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(59) = "Error in sensor element" Unit_Diag_Bit_Help(59) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(60) = "Error in actuator element" Unit_Diag_Bit_Help(60) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(61) = "Faulty installat e.g. dead space" Unit_Diag_Bit_Help(61) = "Check installation." Unit_Diag_Bit(62) = "Parameter setting error" Unit_Diag_Bit_Help(62) = "Check parameter settings for consistency." Unit_Diag_Bit(63) = "Signal path broken or short cut" Unit_Diag_Bit_Help(63) = "Check signal path." Unit_Diag_Bit(64) = "Overloading" Unit_Diag_Bit_Help(64) = "Check load." Unit_Diag_Bit(65) = "Wrong polarity of aux power" Unit_Diag_Bit_Help(65) = "Check polarity." Unit_Diag_Bit(66) = "Maximum line length exceeded" Unit_Diag_Bit_Help(66) = "Check line length." Unit_Diag_Bit(67) = "Corrosion/abrasion by medium" Unit_Diag_Bit_Help(67) = "Replacement is recommended." Unit_Diag_Bit(68) = "Fouling on sensor element" Unit_Diag_Bit_Help(68) = "Cleaning is recommended." Unit_Diag_Bit(69) = "Auxil medium missing or insuffic" Unit_Diag_Bit_Help(69) = "Check auxiliary medium." Unit_Diag_Bit(70) = "Wear reserve used up (operation)" Unit_Diag_Bit_Help(70) = "Plan maintenance." Unit_Diag_Bit(71) = "Wear reserve used up (wear)" Unit_Diag_Bit_Help(71) = "Plan maintenance." Unit_Diag_Bit(72) = "Error in peripherals" Unit_Diag_Bit_Help(72) = "Check peripherals." Unit_Diag_Bit(73) = "Electromag interference too high" Unit_Diag_Bit_Help(73) = "Lower external electromagnetic interference." Unit_Diag_Bit(74) = "Temperature of medium too high" Unit_Diag_Bit_Help(74) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(75) = "Ambient temperature too high" Unit_Diag_Bit_Help(75) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(76) = "Vibration/Impact load too high" Unit_Diag_Bit_Help(76) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(77) = "Auxiliary power range off-spec" Unit_Diag_Bit_Help(77) = "Check power supply" Unit_Diag_Bit(78) = "Auxiliary medium missing" Unit_Diag_Bit_Help(78) = "Check auxiliary medium." Unit_Diag_Bit(79) = "Excessive temperature shock" Unit_Diag_Bit_Help(79) = "Check that the device is operated within its \ specifications." Unit_Diag_Bit(80) = "Deviation from measurement" Unit_Diag_Bit_Help(80) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(81) = "Humidity in electronics area" Unit_Diag_Bit_Help(81) = "Replacement is recommended." Unit_Diag_Bit(82) = "Medium in electronics area" Unit_Diag_Bit_Help(82) = "Replacement is recommended." Unit_Diag_Bit(83) = "Mechanical damage" Unit_Diag_Bit_Help(83) = "Replacement is recommended." Unit_Diag_Bit(84) = "Communication error" Unit_Diag_Bit_Help(84) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." Unit_Diag_Bit(85) = "Foreign material in electro area" Unit_Diag_Bit_Help(85) = "Replacement is recommended." ;NE107_BUOYANCY (device specific) Unit_Diag_Bit(104) = "Gas density change above liquid" Unit_Diag_Bit_Help(104) = "1. Check process conditions. \ 2. Check configuration/calibration." Unit_Diag_Bit(105) = "Vibration/strokes from outside" Unit_Diag_Bit_Help(105) = "1. Reduce vibrations/strokes. 2. Check installation\ instructions for hints to reduce influences of vibrations/strokes." Unit_Diag_Bit(106) = "Displacer partly inside compartm" Unit_Diag_Bit_Help(106) = "Check installation according to the installation \ instructions of the manufacturer." Unit_Diag_Bit(107) = "Displacer too heavy/too light" Unit_Diag_Bit_Help(107) = "Check installation according to the installation \ instructions of the manufacturer." Unit_Diag_Bit(108) = "Density change or displac config" Unit_Diag_Bit_Help(108) = "1. Check process conditions. 2. Check/adapt \ configuration. 3. New calibration might be necessary." Unit_Diag_Bit(109) = "Sticking of torque or spring" Unit_Diag_Bit_Help(109) = "Maintenance is necessary." Unit_Diag_Bit(110) = "Displacer swinging freedomly" Unit_Diag_Bit_Help(110) = "Check installation according to the installation \ instructions of the manufacturer." Unit_Diag_Bit(111) = "Displac mounting faulty" Unit_Diag_Bit_Help(111) = "Replacement is recommended." Unit_Diag_Bit(112) = "Displacer blocked or bended" Unit_Diag_Bit_Help(112) = "Maintenance is necessary." Unit_Diag_Bit(113) = "Displacer too light, corrosion" Unit_Diag_Bit_Help(113) = "Replacement is recommended." Unit_Diag_Bit(114) = "Displacer leakage" Unit_Diag_Bit_Help(114) = "Replacement is recommended." Unit_Diag_Bit(115) = "Force sensor broken" Unit_Diag_Bit_Help(115) = "Replacement is recommended." ;--------------- UnitDiagType=254 X_Unit_Diag_Bit(35) = "Restart" ;DIA_WARMSTART X_Unit_Diag_Bit(36) = "Application reset" ;DIA_COLDSTART X_Unit_Diag_Bit(37) = "Maintenance required" ;DIA_MAINTENANCE X_Unit_Diag_Bit(40) = "Maintenance alarm" ;DIA_MAINTENANCE_ALARM X_Unit_Diag_Bit(41) = "Maintenance demanded" ;DIA_MAINTENANCE_DEMANDED X_Unit_Diag_Bit(42) = "Function check" ;DIA_FUNCTION_CHECK X_Unit_Diag_Bit(43) = "Out of specification" ;DIA_OUT_OF_SPEC X_Unit_Diag_Bit(44) = "Parameter update" ;DIA_UPDATE_EVENT X_Unit_Diag_Bit(55) = "Extension available" ;--- NE107_COMMON X_Unit_Diag_Bit(56) = "Sensor element exciter faulty" X_Unit_Diag_Bit_Help(56) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(57) = "Error in evaluation electronics" X_Unit_Diag_Bit_Help(57) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(58) = "Error in internal energy supply" X_Unit_Diag_Bit_Help(58) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(59) = "Error in sensor element" X_Unit_Diag_Bit_Help(59) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(60) = "Error in actuator element" X_Unit_Diag_Bit_Help(60) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(61) = "Faulty installat e.g. dead space" X_Unit_Diag_Bit_Help(61) = "Check installation." X_Unit_Diag_Bit(62) = "Parameter setting error" X_Unit_Diag_Bit_Help(62) = "Check parameter settings for consistency." X_Unit_Diag_Bit(63) = "Signal path broken or short cut" X_Unit_Diag_Bit_Help(63) = "Check signal path." X_Unit_Diag_Bit(64) = "Overloading" X_Unit_Diag_Bit_Help(64) = "Check load." X_Unit_Diag_Bit(65) = "Wrong polarity of aux power" X_Unit_Diag_Bit_Help(65) = "Check polarity." X_Unit_Diag_Bit(66) = "Maximum line length exceeded" X_Unit_Diag_Bit_Help(66) = "Check line length." X_Unit_Diag_Bit(67) = "Corrosion/abrasion by medium" X_Unit_Diag_Bit_Help(67) = "Replacement is recommended." X_Unit_Diag_Bit(68) = "Fouling on sensor element" X_Unit_Diag_Bit_Help(68) = "Cleaning is recommended." X_Unit_Diag_Bit(69) = "Auxil medium missing or insuffic" X_Unit_Diag_Bit_Help(69) = "Check auxiliary medium." X_Unit_Diag_Bit(70) = "Wear reserve used up (operation)" X_Unit_Diag_Bit_Help(70) = "Plan maintenance." X_Unit_Diag_Bit(71) = "Wear reserve used up (wear)" X_Unit_Diag_Bit_Help(71) = "Plan maintenance." X_Unit_Diag_Bit(72) = "Error in peripherals" X_Unit_Diag_Bit_Help(72) = "Check peripherals." X_Unit_Diag_Bit(73) = "Electromag interference too high" X_Unit_Diag_Bit_Help(73) = "Lower external electromagnetic interference." X_Unit_Diag_Bit(74) = "Temperature of medium too high" X_Unit_Diag_Bit_Help(74) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(75) = "Ambient temperature too high" X_Unit_Diag_Bit_Help(75) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(76) = "Vibration/Impact load too high" X_Unit_Diag_Bit_Help(76) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(77) = "Auxiliary power range off-spec" X_Unit_Diag_Bit_Help(77) = "Check power supply" X_Unit_Diag_Bit(78) = "Auxiliary medium missing" X_Unit_Diag_Bit_Help(78) = "Check auxiliary medium." X_Unit_Diag_Bit(79) = "Excessive temperature shock" X_Unit_Diag_Bit_Help(79) = "Check that the device is operated within its \ specifications." X_Unit_Diag_Bit(80) = "Deviation from measurement" X_Unit_Diag_Bit_Help(80) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(81) = "Humidity in electronics area" X_Unit_Diag_Bit_Help(81) = "Replacement is recommended." X_Unit_Diag_Bit(82) = "Medium in electronics area" X_Unit_Diag_Bit_Help(82) = "Replacement is recommended." X_Unit_Diag_Bit(83) = "Mechanical damage" X_Unit_Diag_Bit_Help(83) = "Replacement is recommended." X_Unit_Diag_Bit(84) = "Communication error" X_Unit_Diag_Bit_Help(84) = "1. Restart device. 2. Check if failure recurs. \ 3. Replacement is recommended." X_Unit_Diag_Bit(85) = "Foreign material in electro area" X_Unit_Diag_Bit_Help(85) = "Replacement is recommended." ;NE107_BUOYANCY (device specific) X_Unit_Diag_Bit(104) = "Gas density change above liquid" X_Unit_Diag_Bit_Help(104) = "1. Check process conditions. \ 2. Check configuration/calibration." X_Unit_Diag_Bit(105) = "Vibration/strokes from outside" X_Unit_Diag_Bit_Help(105) = "1. Reduce vibrations/strokes. 2. Check \ installation instructions for hints to reduce influences of vibrations/strokes." X_Unit_Diag_Bit(106) = "Displacer partly inside compartm" X_Unit_Diag_Bit_Help(106) = "Check installation according to the installation \ instructions of the manufacturer." X_Unit_Diag_Bit(107) = "Displacer too heavy/too light" X_Unit_Diag_Bit_Help(107) = "Check installation according to the installation \ instructions of the manufacturer." X_Unit_Diag_Bit(108) = "Density change or displac config" X_Unit_Diag_Bit_Help(108) = "1. Check process conditions. 2. Check/adapt \ configuration. 3. New calibration might be necessary." X_Unit_Diag_Bit(109) = "Sticking of torque or spring" X_Unit_Diag_Bit_Help(109) = "Maintenance is necessary." X_Unit_Diag_Bit(110) = "Displacer swinging freedomly" X_Unit_Diag_Bit_Help(110) = "Check installation according to the installation \ instructions of the manufacturer." X_Unit_Diag_Bit(111) = "Displac mounting faulty" X_Unit_Diag_Bit_Help(111) = "Replacement is recommended." X_Unit_Diag_Bit(112) = "Displacer blocked or bended" X_Unit_Diag_Bit_Help(112) = "Maintenance is necessary." X_Unit_Diag_Bit(113) = "Displacer too light, corrosion" X_Unit_Diag_Bit_Help(113) = "Replacement is recommended." X_Unit_Diag_Bit(114) = "Displacer leakage" X_Unit_Diag_Bit_Help(114) = "Replacement is recommended." X_Unit_Diag_Bit(115) = "Force sensor broken" X_Unit_Diag_Bit_Help(115) = "Replacement is recommended." EndUnitDiagType ;------------------------------------------------------------------------- ; ;max module text length-----------------" Module="Not in cyclic data transfer " 0x00 ;Empty module 0 Info_Text="No cyclic data selected for this slot. Function disabled" EndModule Module="Level" 0x42,0x84,0x08,0x05 1 EndModule ;----------- Description of the module assignment: --------------------- ; SlotDefinition Slot(1) = "" 1 1 EndSlotDefinition