Skip to main content

Download

PROFINET Specification

PROFINET , Security

Description:

Overview and guidance for PROFINET specifications
IEC 61158-1

This document provides the overview and guidance how the IEC 61158 series is structured
and how it is related to the profile documents in the IEC 61784 series.
 

Details:
Version: 2.3
Order No.: 2.702
Language: English
______________________________________________________________

Application layer services for decentralized periphery
IEC 61158-5-10

The application service is provided by the application protocol making use of the services available from the data-link or other immediately lower layer. This document defines the application service characteristics that fieldbus applications and/or system management may exploit.

Details:
Version: 2.4MU4
Order No.: 2.712
Language: English

 

Draft for review:

Details:
Version:   d2.4MU5
Order No.:   2.712
Language: English

This draft is published for testing and review only. It must not be used for development purposes.

Comments to be submitted to www.profibus-project.com  until February 12, 2024.

______________________________________________________________

Application layer protocol for decentralized periphery
IEC 61158-6-10

The application protocol provides the application service by making use of the services available from the data-link or other immediately lower layer. The primary aim of this document is to provide a set of rules for communication expressed in terms of the procedures to be carried out by peer application entities (AEs) at the time of communication.

Details:
Version: 2.4MU4
Order No.: 2.722
Language: English

 

Draft for review:

Details:
Version:   d2.4MU5
Order No.:   2.722
Language: English

This draft is published for testing and review only. It must not be used for development purposes.

Comments to be submitted to www.profibus-project.com  until February 12, 2024.

______________________________________________________________

Profiles for decentralized periphery
IEC 61784–2

This part of IEC 61784 provides additional Communication Profiles (CP) to the existing Communication Profile Families (CPF) of IEC 61784–1. These communication profiles are called Real-Time Ethernet communication profiles.
 

Details:
Version: 2.4MU4
Order No.: 2.742
Language: English

 

Draft for review:

Details:
Version:   d2.4MU5
Order No.:   2.742
Language: English

This draft is published for testing and review only. It must not be used for development purposes.

Comments to be submitted to www.profibus-project.com  until February 12, 2024.

___________________________________________________________________________________________________________________


Main difference to V2.3Ed2MU5 is the integration of Conformance Class “D” to specify PROFINET over TSN.
 

* Integration of IEEE 802 end-station, bridged end-station and bridge models
* Adjustment to definitions of TSN industrial profile
* Class 2 of Security Integration in PROFINET

 

V2.4MU3 mainly focuses on three topics
1. Complete security integration (aligned to IEC/IEEE 60802)
2. IEC/IEEE 60802 conformant end station, bridge, and bridged end station model
3. Enhancements for APL support – avoiding congestion loss

The device model derived from IEEE 802.1Q and a more stringent decoupling of PROFINET
middleware and network interface lead to structural changes in the documents.
➔ This process will be completed in the MU4 with the IEC/IEEE 60802 integration
Complete security integration in Profile, Service and Protocol for all conformance classes.
➔ This process will be completed in the MU4 with the IEC/IEEE 60802 integration
Mixed link speeds are identified as a major threat for creating congestion loss.
➔ Congestion loss prevention completed

 

Main topics for V2.4MU4:

Add application classes Drive and Encoder.

Add Downshift delay and Expected PHY latency variation.

Allow full range for StreamDA destination MAC address.

Adjustment of the DCP filter chaining function.

Adaptation the definition of the required bridge resources to the link-speed and the mandatory buffer time.

Allow the use of link-local IP address according to RFC 3927.

Update the LLDP EXT MIB for MRP interconnection.

Clarification of MRP interconnect encoding.

The IP parameter of the DCP ASE value distinguish between operational and administrative.

Security:

New optional record SNMPReal.

VCI extension for IDevID credentials; used for automated credential commissioning.

Simplify addressing of credential used in record services.

 


***************************************************************************************************************************************************************************************

PROFINET V2.2  is specified in IEC61158-6-10 Ed2.0, IEC61158-5-10 Ed2.0 and IEC61784-2 Ed2.0.
These documents can be purchased from the IEC website by using the following link:

http://webstore.iec.ch/
__________________________________________________________________________________________________________________

The vendors who provide products with Media Redundancy functionality are authorized to make electronic copies of the attached (ASCII readable)
LLDP-EXT-IEC61158-TYPE10-MIB file (contained in the 7z file) as well as to publish them on their websites.
__________________________________________________________________________________________________________________
 

Files:
This area is for members only. Please login to access this download.
# Date Filename Type Size
17/11/2010 Overview-for-PI-specs_2702_V23_Oct10.pdf pdf 720 KB
29/04/2020 MIBs.7z 7z 14 KB
21/06/2023 LLDP-EXT-IEC61158-TYPE10-MIB-20230331.mib mib 75 KB
19/06/2023 PN-AL-services_2712_V24MU4_May23.pdf pdf 8 MB
19/06/2023 PN-AL-protocol_2722_V24MU4_May23.pdf pdf 12 MB
19/06/2023 PN-Profiles_2742_V24MU4_May23.pdf pdf 3 MB
13/11/2023 PN-AL-services-2712-d24MU5-Nov23.pdf pdf 8 MB
13/11/2023 PN-AL-protocol-2722-d24MU5-Nov23.pdf pdf 12 MB
13/11/2023 PN-Profiles-2742-d24MU5-Nov23.pdf pdf 2 MB
13/11/2023 v24MU4_to_v24MU5_changes__PI_Review.pdf pdf 63 KB

PROFIBUS is a standardized, open, digital communications system for all areas of application in manufacturing and process automation.

PROFINET is the innovative open standard for Industrial Ethernet. It satisfies all requirements of automation technology.

MTP Module Type Package enables modular production in which individual components can be flexibly combined.

IO-LINK is an independent sensor / actuator interface solution for use with all automation technologies.

omlox is an open technology standard for real-time indoor localization systems for industrial manufacturing.